Testing the integrity of a vulcanised splice is essential before returning a conveyor system to operation.
Common testing methods
Visual inspection
Checks for:
- Surface defects
- Misalignment
- Incomplete bonding
Thickness and profile checks
Ensures the splice matches the original belt profile to prevent tracking issues.
Tensile strength testing (where applicable)
Measures the load capacity of the splice relative to the belt specification.
Non-destructive testing
Used in critical applications to detect internal bonding issues.
Why testing matters
A splice may appear intact but still fail under load if not properly tested. Verification ensures operational reliability.